<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-28 07-09-31
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 50 dBuV VOLTAGE
Pilot RDS Phase Difference
7.2 kHz 3.9 kHz 19 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
13 kHz 73 kHz 7418 57,2661
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,5 dBr 7,33 dBr 7,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 7:09, 28.12.2024
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (50 dBuV) Max at: 73 kHz MIN: 13 kHz % above 75 kHz: 57,2661 Acquired: 2024/12/28 7:08:27 Total samples: 7418 Equivalent time: 0:06:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 7,7 dBr MIN: 6,5 dBr AVE: 7,33 dBr % above 10,0 dBr: 0,0 Last value: 7,0 dBr (2024/12/28 7:08:27) Station: 96.90 MHz, signal: 4/5 (50 dBuV) 07:02 07:03 07:04 07:05 07:06 07:07 07:08 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality